| Commercial message | |
| | |
| BTC/ Emprex Burner If you are the lucky owner of a BTC burner or an Emprex burner and have a problem, comment or suggestion then discuss BTC and Exmprex recording hardware on CD Freaks |
![]() |
| | Thread Tools |
| | #1 (permalink) |
| New on Forum Join Date: Oct 2003
Posts: 23
| firmware 045 on memup drive? Hi, I've a friend that own the memup drive, which is a BTC as i understood. Can he flash is drive with the last firmware released by BTC? On Memup web site, the only firmware available is the fw_039btc_dual4x.zip. Thanks. |
| |
| | #3 (permalink) |
| CD Freaks Member Join Date: Nov 2003 Location: Madrid, SPAIN
Posts: 135
| True, but if warranty issues don't worry you, all you have to do is unzip the fw_039btc_dual4x.zip file and replace the Memup0039.hex with the DRV045.HEX included in the latest BTC firmware package. Starting versions 038/039 the new firmware IDs are identical "DVDRW IDE1004", and only the flashers provided by the OEMs will detect the previous firmware ID, in your case it's "Memup DRW1004IM". Once done, you can simply download any BTC update and flash it directly and forget about Memup's site. |
| |
| | #5 (permalink) | |
| New on Forum Join Date: Nov 2003
Posts: 11
| Quote:
I hope Memup will update his support site soon . | |
| |
| | #7 (permalink) |
| New on Forum Join Date: Nov 2003
Posts: 11
| I'm not at home at the moment but if i remember , it doesn't said " It's only for Memup DRW1004IM" . I use the updater from fw_039btc_dual4x.zip , but instead of loading the 039 file , i load the 045 , but after a click on upgrade , i have a message like this " wrong firmware version " . |
| |
| | #8 (permalink) |
| CD Freaks Member Join Date: Nov 2003 Location: Madrid, SPAIN
Posts: 135
| But have you upgraded to Memup's version 39 yet? What's your current release? BTW, BTC's version 45 is an autoextractor and you have to find the file in your windows/temp directory. I suppose that's what you did. |
| |
| | #9 (permalink) |
| CD Freaks Member Join Date: Nov 2003 Location: Madrid, SPAIN
Posts: 135
| Another trick that might work. This time, simply use BTC's v45 autoextractor. With this release, they've completely changed the way the flasher works. The firmware ID string verifier is not internally included in the flasher now; instead, there's an external IDString.txt file that comes with it (or generated at runtime). The text file says: "DVDRW IDE1004 ""Drv045.hex""Y" You'll have to change the contents of the first quote to your recorders' ID string to something like: "Memup DRW1004IM ""Drv045.hex""Y" (Note: make sure there are 24 characters within the first quote; there are three spaces between 'Memup' and 'DRW1004IM' and 7 spaces between 'DRW1004IM' and the last ' " '. This hold true ONLY if your firmware ID string is as stated above) So what you should try is (step-by-step): 1) Empty your Windows TEMP folder 2) Double-click on the self extractor then exit immediately. 3) Look for the newly created folder INSIDE your TEMP folder. You should find the following files: DRV045.HEX, FIDE.SYS, FIDEVXD.VXD, IDEFLASH.EXE and IDSTRING.TXT 4) Modify the IDSTRING.TXT as mentioned above and save it. 5) Now run IDEFLASH.EXE This time it shouldn't complain. NOTE: adapt "Memup DRW1004IM " to whatever your exact firmware ID string currently is. Last edited by ajz; 14-11-2003 at 13:36. |
| |
| |
| |
![]() |
| Bookmarks |
| Thread Tools | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Memup to BTC possible ? | trouson | BTC/ Emprex Burner | 1 | 28-02-2005 08:31 |
| did someone try dvd-r ARITA RITEKG04 on emprex/btc/memup 4x | fifilaplume | BTC/ Emprex Burner | 1 | 25-02-2004 00:38 |
| Memup IDE1008 same as BTC 1008 ? | Fleau | BTC/ Emprex Burner | 7 | 18-02-2004 20:41 |
| problems with external memup kobalt dual usb2.0 | nengwalf | BTC/ Emprex Burner | 3 | 19-12-2003 18:49 |
| HELP - Who have DOS flash updater cause DRW1004 dead after 045 | dp_1999 | BTC/ Emprex Burner | 3 | 24-11-2003 17:24 |